What Size Screw Air Compressor Do I Need? CFM, Pressure and HP

Published on

What size screw air compressor do I need?

The short answer: size the compressor on air flow (CFM) at your working pressure, not on motor HP. Add up the air used by everything that runs at the same time, add about 20%, decide the pressure the compressor must hold, and pick the model whose free air delivery (FAD) at that pressure is at or just above your figure. As a rough check, a Colt single-stage screw compressor gives about 4.5 to 5 CFM per HP at 8 bar, and less at 10 or 13 bar.

Many enquiries we get start with a motor size: "we need a 50 HP compressor". The HP tells you what the machine costs to run, not whether it will keep your plant supplied. Here is how we size a screw compressor, step by step.

Why HP alone is the wrong starting point

Two things decide whether a compressor is big enough: how much air it delivers, and at what pressure. The same motor gives less air as the pressure goes up.

Take our CS 50, a 50 HP (37 kW) machine. At 8 bar it delivers 242.4 CFM. At 13 bar it delivers 193 CFM, about 20% less, from the same motor. So a buyer who needs 300–350 CFM at 8 bar won't get it from a 50 HP screw. A 60 HP machine gives 280.6 CFM, still short. A 75 HP gives 358 CFM, which covers it.

Always compare FAD, the air actually delivered at the outlet, measured at the stated pressure. Our figures are measured to ISO 1217 Annex C. If a quote shows only "displacement" or only HP, ask for the FAD at your pressure.

Step 1: work out how much air you use

For a new plant or a new line, list every machine that uses air, with its consumption in CFM from the maker's data sheet. Then ask which of them run at the same time. Ten machines that each use 20 CFM don't need 200 CFM if only six ever run together. Add up the ones that run together, then add about 20% to cover leaks, wear and some growth.

For a plant that is already running, measure instead of guessing. The simplest way is the load/unload test on your present compressor: time how long it runs loaded and unloaded during normal production. If a 240 CFM compressor runs loaded 80% of the time at peak, your peak demand is about 190 CFM. Our compressed air leak calculator and leak cost guide explain the test.

Run the same test with production stopped, too. Whatever the compressor makes then is going into leaks. Fix them before buying, or the new compressor will be sized to feed the leaks.

Step 2: decide the pressure

Find the highest pressure any of your regular machines needs at its inlet. Most pneumatic tools and machines work at 6–7 bar. Then allow for the pressure lost through the dryer, filters and piping between the compressor and the machine, usually about 1 bar in a well-laid system. That gives the pressure the compressor must hold: for a 7 bar machine, set the compressor around 8 bar.

Don't add more than you need. Every extra 1 bar costs roughly 6–7% more power, every hour the compressor runs. If the pressure at the far end of the plant is low, check the piping and filters before turning the compressor up.

If only one machine needs a much higher pressure, give it its own compressor instead of running the whole plant at that pressure. For example, laser cutting machines need 16 bar; see our 16 bar screw compressors for laser cutting. PET bottle blowing needs 40 bar air; see our PET bottling air compressors.

Step 3: pick the model from the FAD table

With your CFM and pressure, read across the table and pick the first model that meets both. These are our fixed-speed single-stage screw compressors, from the screw air compressor page:

ModelMotor (HP / kW)FAD at 8 bar (CFM)FAD at 10 bar (CFM)FAD at 13 bar (CFM)
CS 10 FS10 / 7.542.236.028.2
CS 15 FS15 / 1169.458.052.8
CS 20 FS20 / 1590.776.268.9
CS 25 FS25 / 18.5114.296.885.4
CS 30 FS30 / 22132.0114.2100.8
CS 40 FS40 / 30198.2175.8160.4
CS 50 FS50 / 37242.4213.8193.0
CS 60 FS60 / 45280.6236.3211.2
CS 75 FS75 / 55358.0324.0260.8
CS 100 FS100 / 75477.2412.6342.2
CS 120 FS120 / 90594.0506.0472.0
CS 150 FS150 / 110698.0588.0539.0
CS 180 FS180 / 132832.0682.0578.0

Our screw range runs from 10 to 350 HP; models above 180 HP have their own data sheets, so ask us for them.

Step 4: fixed speed, VFD or two-stage?

The size tells you how much air. The type decides what that air costs.

  • Fixed speed suits a plant whose demand stays close to the machine's full output through the shift. It is the lowest purchase price. When demand drops it runs unloaded, and an unloaded screw compressor still draws 20–30% of its full power while making no air.
  • VFD suits a plant whose demand swings. The machine slows down instead of unloading, and can save up to 35% of the energy. Size it so its top FAD at your pressure covers your peak, and check that your usual demand sits between about 40% and 100% of its range. See VFD screw air compressors.
  • Two-stage suits large plants running round the clock. It gives about 15–20% more air per HP than a single-stage machine. Our two-stage VFD machines run from 30 to 350 HP. See two-stage vs single-stage screw compressors.

Many plants do well with one fixed-speed machine for the steady base load and one VFD machine to follow the swings. That also means the plant isn't left without air when one machine is being serviced.

Step 5: size the receiver, dryer and filters with it

The air treatment has to match the compressor's full output, not your average demand.

  • Air receiver: 500 L up to 30 HP, 1,000 L from 40 to 100 HP, 2,000 L from 120 HP. Our air receiver sizing guide has the detail.
  • Refrigerated dryer and line filters: rated for at least the compressor's full FAD at your pressure. Dryer ratings fall when the inlet air and the compressor room are hot, so in an Indian summer choose one size up. See our air dryers, filters and receivers.

A worked example

A plant has machines that use 240 CFM when everything that runs together is on. Its machines need 7 bar.

  1. Air: 240 CFM + 20% = 288 CFM.
  2. Pressure: 7 bar at the machine + about 1 bar for dryer, filters and piping = 8 bar at the compressor.
  3. Model: at 8 bar, the CS 60 gives 280.6 CFM, just short. The CS 75 gives 358 CFM, so the CS 75 (75 HP / 55 kW) is the fit.
  4. Type: demand runs between 150 and 288 CFM through the day, so a CS 75 VFD (143.2–358 CFM at 8 bar) follows it without running unloaded.
  5. Treatment: a 1,000 L receiver, and a dryer and filters rated for at least 358 CFM at 8 bar, one size up if the compressor room runs hot.

If the plant measured 30 CFM of leaks and fixed them first, the smaller machine might do. That is why we ask for a load/unload test before quoting on an existing plant. To see what the chosen machine will cost to run, use our screw compressor running cost guide.

Frequently Asked Questions

On our single-stage machines, about 4.5 to 5 CFM per HP at 8 bar. It drops as pressure rises: our CS 50 gives 242.4 CFM at 8 bar and 193 CFM at 13 bar. A two-stage machine gives about 15–20% more air per HP.

A little margin is good, and that is what the 20% covers. Much more than that costs you every day: a fixed-speed machine that is too big spends long hours unloaded, drawing 20–30% of its full power while making no air. If your demand varies a lot, a VFD machine is a better answer than a bigger one.

The lowest that covers your highest regular machine pressure plus about 1 bar for the dryer, filters and piping. For most plants with 6–7 bar machines, that is 8 bar. Each extra bar adds roughly 6–7% to the power bill.

Single-stage screw air compressors from 10 to 350 HP, in fixed-speed and VFD versions, two-stage VFD machines from 30 to 350 HP, and 16 bar VFD machines for laser cutting. The catalogue table covers 10 to 180 HP; ask us for larger models.

Get your compressor sized

Send us the list of machines that use air (or your load/unload timings), the working pressure, your running hours and your electricity tariff through our contact page. Our engineers will suggest the compressor, receiver, dryer and filters, with the running cost.